• Portal do Governo Brasileiro

Plataforma Sucupira

Dados do Trabalhos de Conclusão

UNIVERSIDADE FEDERAL DO RIO DE JANEIRO
ODONTOLOGIA (31001017059P2)
Educação Presencial
EXPANSÃO RÁPIDA DA MAXILA APOIADA EM MINI-IMPLANTES (MARPE): EFEITOS DA ANCORAGEM BICORTICAL (IN VITRO) E ANÁLISE CLÍNICA DA ESPESSURA ÓSSEA ALVEOLAR VESTIBULAR ATRAVÉS DE REVISÃO SISTEMÁTICA E META-ANÁLISE
FLAVIO DE MENDONCA COPELLO
TESE
13/07/2022

O objetivo desse estudo foi avaliar, in vitro, a influência mecânica do tipo de ancoragem (monocortical ou bicortical), utilizada na técnica de expansão rápida da maxila apoiada em mini-implantes (MARPE), na microarquitetura óssea trabecular onde o disjuntor é instalado, e, analisar, através de revisão sistemática e meta-análise, os efeitos desta técnica na espessura da tábua óssea vestibular dos dentes de suporte, comparando com a técnica de expansão convencional. Dezesseis mini-implantes do tipo auto-perfurantes foram distribuídos em dois grupos (dois dispositivos MARPE com 4 mini-implantes cada grupo) de acordo com o tipo de inserção óssea (monocortical e bicortical), instalados em osso de costela bovina, e, ativados em cinco tempos distintos onde a cada ativação, o corpo de prova era microtomografado. O espaçamento das trabéculas (Tb.Sp [mm]) foi o parâmetro utilizado para avaliar a microarquitetura óssea em cinco regiões de interesse (ROI) peri-implantar (osso ao redor do dispositivo, superior, inferior, anterior e posterior). O teste ANOVA two-way com análise post-hoc de Tukey (α = 0,05) foi usado para avaliar o efeito do tipo de inserção na microarquitetura óssea durante os ciclos de ativação. O efeito do tempo foi avaliado usando o teste ANOVA-MR com correção de Bonferroni (α = 0,003). Para responder à pergunta da revisão sistemática (o osso alveolar vestibular é menos afetado pela técnica MARPE do que pela expansão rápida da maxila convencional?), as bases PubMed (MEDLINE), Scopus, Web of Science, The Cochrane Library, Virtual Health Library e OpenGrey foram utilizadas até março de 2019. Avaliações de risco de viés foram realizadas usando as ferramentas Cochrane Collaboration e ROBINS-I. No estudo in vitro, apenas o ROI superior (cervical) teve diferença significativa (p <0,003) após o quarto ciclo de ativação ao longo do tempo entre as ativações. Para o grupo monocortical, o espaçamento trabecular foi afetado quando todo o ROI foi analisado a partir do quarto ciclo de ativação, enquanto para o ROI superior, essa diferença tornou-se aparente a partir do terceiro ciclo de ativação (p <0,003). Em relação a revisão sistemática, as evidências limitadas indicaram que pacientes tratados com a técnica convencional tiveram uma perda maior da espessura óssea alveolar vestibular em comparação com pacientes usando MARPE (p=0,001). As análises de subgrupo mostraram que as diferenças foram significativas em ambas as regiões de pré-molares, direita (p = 0,004) e esquerda (p <0,0001). Baseado nos resultados encontrados pode-se concluir que a ancoragem monocortical é mais suscetível a danos ósseos ao redor dos mini-implantes, sendo a região superior mais afetada. Assim como, evidências limitadas sugerem que o MARPE pode diminuir a perda do osso alveolar vestibular quando comparado a técnica de expansão convencional.

Ancoragem Ortodôntica;Expansão rápida da maxila;Teste de materiais;Meta-análise
This study aimed to evaluate, in vitro, the mechanical influence of the type of anchorage (monocortical or bicortical), that is used in the mini-implant assisted rapid palatal expansion (MARPE) technique, on the trabecular bone microarchitecture where the appliance is installed, and to analyze, through systematic review and meta-analysis, the effects of this technique on the buccal palatal bone thickness of the supporting teeth, compared to the conventional technique. Sixteen self-drilling mini-implants were distributed into two groups (two MARPE devices with 4 mini-implants each group) according to the type of bone insertion (monocortical and bicortical), installed in bovine rib bone, and activated five different times where at each activation, the specimen was microtomographed. Trabecular spacing (Tb.Sp [mm]) was the parameter used to assess bone microarchitecture in five peri-implant regions of interest (ROI) (the whole area around the device, superior, inferior, anterior ,and posterior ). The two-way ANOVA test with post-hoc Tukey analysis (α = 0.05) was used to assess the effect of insertion type on bone microarchitecture during activation cycles. The effect of time was evaluated using the ANOVA-MR test with Bonferroni correction (α = 0.003). To answer the systematic review question (is the buccal alveolar bone less affected by mini-implant assisted rapid palatal expansion than by conventional rapid palatal expansion?), PubMed (MEDLINE), Scopus, Web of Science, The Cochrane Library, Virtual Health Library and OpenGrey databases were used for research until March 2019. Bias risk assessments were performed using the Cochrane Collaboration and ROBINS-I tools. In the in vitro study, only the superior (cervical) ROI had a significant difference (p<0.003) after the fourth activation cycle. For the monocortical group, trabecular spacing was affected when the whole area ROI was analyzed from the fourth activation cycle, on the other hand, when analyzing the superior ROI, this difference was significant from the third activation over time between the actvations (p<0.003). Regarding the systematic review, limited evidence indicated that patients treated with the conventional technique had a greater loss of buccal alveolar bone thickness compared to patients treated with the MARPE technique (p=0.001). Subgroup analyzes showed that differences were significant in both the right (p = 0.004) and left (p < 0.0001) premolar regions. Based on the results found, it can be concluded that monocortical anchorage is more susceptible to bone damage around the mini-implants, and the superior region is more affected. As well, limited evidence suggests that MARPE technique may reduce the loss of buccal alveolar bone when compared to the conventional palatal expansion technique.
Orthodontic anchorage;Rapid maxillary expansion;Materials Testing;Meta-analysis
1
51
PORTUGUES
UNIVERSIDADE FEDERAL DO RIO DE JANEIRO
O trabalho possui divulgação autorizada
Tese de Doutorado_FINAL.pdf

Contexto

ORTODONTIA
FATORES INFLUENTES E RESULTADOS DOS TRATAMENTOS ORTODÔNTICOS.
PESQUISAS CLÍNICAS E LABORATORIAIS DE FATORES RELACIONADOS COM O TRATAMENTO ORTODÔNTICO.

Banca Examinadora

EDUARDO FRANZOTTI SANT ANNA
DOCENTE - PERMANENTE
Sim
Nome Categoria
MONICA TIRRE DE SOUZA ARAUJO Docente - PERMANENTE
AMANDA CUNHA REGAL DE CASTRO Docente - PERMANENTE
EDUARDO FRANZOTTI SANT ANNA Docente - PERMANENTE
LUCIANA DUARTE CALDAS Pós-Doc
PEDRO LIMA EMMERICH OLIVEIRA Egresso - Doutorado

Financiadores

Financiador - Programa Fomento Número de Meses
FUND COORD DE APERFEICOAMENTO DE PESSOAL DE NIVEL SUP - Programa de Demanda Social 44

Vínculo

CLT
Instituição de Ensino e Pesquisa
Ensino e Pesquisa
Sim
Plataforma Sucupira
Capes UFRN RNP
  • Compatibilidade
  • . . .
  • Versão do sistema: 3.87.0
  • Copyright 2022 Capes. Todos os direitos reservados.

Nós usamos cookies para melhorar sua experiência de navegação no portal. Ao utilizar o gov.br, você concorda com a política de monitoramento de cookies. Para ter mais informações sobre como isso é feito, acesse Política de cookies.Se você concorda, clique em ACEITO.

Politica de Cookies

O que são cookies?

Cookies são arquivos salvos em seu computador, tablet ou telefone quando você visita um site.Usamos os cookies necessários para fazer o site funcionar da melhor forma possível e sempre aprimorar os nossos serviços. Alguns cookies são classificados como necessários e permitem a funcionalidade central, como segurança, gerenciamento de rede e acessibilidade. Estes cookies podem ser coletados e armazenados assim que você inicia sua navegação ou quando usa algum recurso que os requer.

Cookies Primários

Alguns cookies serão colocados em seu dispositivo diretamente pelo nosso site - são conhecidos como cookies primários. Eles são essenciais para você navegar no site e usar seus recursos.
Temporários
Nós utilizamos cookies de sessão. Eles são temporários e expiram quando você fecha o navegador ou quando a sessão termina.
Finalidade
Estabelecer controle de idioma e segurança ao tempo da sessão.

Cookies de Terceiros

Outros cookies são colocados no seu dispositivo não pelo site que você está visitando, mas por terceiros, como, por exemplo, os sistemas analíticos.
Temporários
Nós utilizamos cookies de sessão. Eles são temporários e expiram quando você fecha o navegador ou quando a sessão termina.
Finalidade
Coletam informações sobre como você usa o site, como as páginas que você visitou e os links em que clicou. Nenhuma dessas informações pode ser usada para identificá-lo. Seu único objetivo é possibilitar análises e melhorar as funções do site.

Você pode desabilitá-los alterando as configurações do seu navegador, mas saiba que isso pode afetar o funcionamento do site.

Chrome

Firefox

Microsoft Edge

Internet Explorer