• Portal do Governo Brasileiro

Plataforma Sucupira

Dados do Trabalhos de Conclusão

UNIVERSIDADE FEDERAL DO PARÁ
SAÚDE ANIMAL NA AMAZÔNIA (15001016057P4)
Videolaparoscopia das estruturas umbilicais de fetos bovinos: marsupialização da veia umbilical e sutura percutânea em modelo experimental
CARLA ROZILENE GUIMARAES SILVA
TESE
31/03/2022

Os bezerros recém nascidos acometidos por distúrbios umbilicais podem receber o tratamento de onfaloflebite e de abscessos hepáticos através da marsupialização da veia umbilical e em casos de hérnias umbilicais, a herniorrafia umbilical, ambas por laparotomia. A laparoscopia possibilita a visualização completa e rápida da cavidade abdominal, com menos danos comparado às técnicas convencionais. O objetivo deste trabalho é descrever a técnica de marsupialização da veia umbilical videoassistida, estabelecer um modelo de estudo e avaliar a viabilidade da técnica de sutura percutânea da parede abdominal de forma videoassistida em fetos bovinos (cadáveres), comparando com a técnica convencional. No experimento 01, foram utilizados 16 fetos bovinos, divididos no grupo controle, submetidos à técnica de marsupialização da veia umbilical por laparotomia e no grupo videocirúrgico. No experimento 02, 16 bezerros divididos no grupo controle, submetidos à técnica de abdominorrafia umbilical por laparotomia e no grupo videocirúrgico, técnica de sutura percutânea da parede abdominal. Foi criada uma lesão na parede abdominal para realizar a correção de forma laparoscópica. Em ambas as técnicas houve diferença estatística no tempo de acesso à cavidade abdominal, mais rápido por laparotomia. A criação do modelo de estudo permitiu a execução da técnica de sutura percutânea da parede abdominal de forma videoassistida. Para execução das técnicas não houve diferença estatística entre os grupos. O fechamento da cavidade abdominal influenciando no maior tempo cirúrgico total, mas rápido nos grupos videocirúrgicos. As técnicas laparorópicas propostas em nosso trabalho permitiram a realização do pinçamento, diérese e marsupialização da veia umbilical, além da criação de um modelo de estudo para a realização da herniorrafia umbilical de forma videoassistida com dois portais com menor tempo cirúrgico comparado à técnica convencional.

bezerros,;hérnia umbilical,;laparoscopia,;modelo de estudo,;onfaloflebite
Newborn calves affected by umbilical pathologies can receive treatment for omphalophlebitis and liver abscesses throughmarsupialization of the umbilical vein and in cases of umbilical hernias, umbilical herniorrhaphy, both performed by laparotomy.the laparoscopyallows the complete and rapid visualization of the abdominal cavity, being less invasive when compared to conventional techniques. In this sense, the objective of the present study was to describe the video-assisted umbilical vein marsupialization technique, establish an experimental model and evaluate the viability of the video-assisted percutaneous suture technique of the abdominal wall in bovine fetuses (corpses) and compare with the conventional technique. In both experiments, 16 bovine fetuses were used, from pregnant cows slaughtered in slaughterhouses. In experiment 1, the fetuses were divided into two groups according to the umbilical vein marsupialization technique: open surgery by laparotomy group (OP, n=08) and the laparoscopy surgery group (LA, n=08), with two lateral accesses. on the right flank. In experiment 2, the fetuses were divided into a control group (CG, n=8), submitted to the technique of umbilical abdominorrhaphy by laparotomy and in the video-surgical group (VG, n=8), video-assisted percutaneous suture, with two lateral accesses in the flank right. In both groups, abdominal wall defects were created as an experimental model. Subsequently, the defects were corrected. In both techniques there wasstatistical difference in the time of access to the abdominal cavity, faster by laparotomy and for the execution of the techniques there was no statistical difference between the groups. Experiment 1, there was a statistical difference in the time of access to the abdominal cavity until the visualization of the umbilical vein and adjacent structures in the OP group was 3.65 minutes and in the LA group, 4.73 minutes, with p < 0.0001. There was no statistical difference in the time of umbilical vein clamping, diaeresis and marsupialization by laparotomy and laparoscopy. The surgical time for closing the abdominal cavity was longer in the OP group than in the LA group, showing a statistically significant difference (p < 0.0001). The total surgical time was statistically longer (p < 0.0001) in the OP group (35.41 ± 0.58 min) compared to the LA group (12.00 ± 0.45 min). In experiment 2, access time until the umbilical base was visualized was longer in the LA group, with the surgical time of 4.73 minutes and in the OP group it was 3.65 minutes, with p < 0.0001. Experiment 2 there was no statistically significant differencein step 1 between groups. In step 2 there wassignificant statistical difference (p < 0.0001) the surgical time of this step was longer in the GC group (33.10 ± 0.43 minutes) than in the GV group (10.13 ± 0.68 minutes) and in the total surgical time (p < 0.0001), higher in the GC group (38.48 ± 0.35 minutes) when compared to the GV group (15.86 ± 0.67 minutes). The laparoscopic techniques proposed in our work allowed the performance of clamping, diaeresis and marsupialization of the umbilical vein, in addition to the creation ofcreation of an experimental model for carrying out thevideo-assisted percutaneous suture with two portals, with less surgical time compared to the conventional technique.
calves, laparoscopy, omphalophlebitis, study model, umbilical hérnia
1
52
PORTUGUES
UNIVERSIDADE FEDERAL DO PARÁ
O trabalho não possui divulgação autorizada

Contexto

SÁUDE ANIMAL
PROCESSO SAÚDE-DOENÇA NOS ANIMAIS
Atendimento clínico e estudo em especialidade de cirurgia e diagnóstico veterinário, com ênfase em videocirurgia e videodiagnóstico

Banca Examinadora

PEDRO PAULO MAIA TEIXEIRA
DOCENTE - PERMANENTE
Sim
Nome Categoria
MARCO AUGUSTO MACHADO SILVA Participante Externo
LUISA GOUVEA TEIXEIRA Participante Externo
FELIPE MASIERO SALVARANI Docente - PERMANENTE
PEDRO PAULO MAIA TEIXEIRA Docente - PERMANENTE
RINALDO BATISTA VIANA Participante Externo

Financiadores

Financiador - Programa Fomento Número de Meses
FUND COORD DE APERFEICOAMENTO DE PESSOAL DE NIVEL SUP - Programa de Demanda Social 36

Vínculo

Servidor Público
Instituição de Ensino e Pesquisa
Ensino e Pesquisa
Sim
Plataforma Sucupira
Capes UFRN RNP
  • Compatibilidade
  • . . .
  • Versão do sistema: 3.86.1
  • Copyright 2022 Capes. Todos os direitos reservados.

Nós usamos cookies para melhorar sua experiência de navegação no portal. Ao utilizar o gov.br, você concorda com a política de monitoramento de cookies. Para ter mais informações sobre como isso é feito, acesse Política de cookies.Se você concorda, clique em ACEITO.

Politica de Cookies

O que são cookies?

Cookies são arquivos salvos em seu computador, tablet ou telefone quando você visita um site.Usamos os cookies necessários para fazer o site funcionar da melhor forma possível e sempre aprimorar os nossos serviços. Alguns cookies são classificados como necessários e permitem a funcionalidade central, como segurança, gerenciamento de rede e acessibilidade. Estes cookies podem ser coletados e armazenados assim que você inicia sua navegação ou quando usa algum recurso que os requer.

Cookies Primários

Alguns cookies serão colocados em seu dispositivo diretamente pelo nosso site - são conhecidos como cookies primários. Eles são essenciais para você navegar no site e usar seus recursos.
Temporários
Nós utilizamos cookies de sessão. Eles são temporários e expiram quando você fecha o navegador ou quando a sessão termina.
Finalidade
Estabelecer controle de idioma e segurança ao tempo da sessão.

Cookies de Terceiros

Outros cookies são colocados no seu dispositivo não pelo site que você está visitando, mas por terceiros, como, por exemplo, os sistemas analíticos.
Temporários
Nós utilizamos cookies de sessão. Eles são temporários e expiram quando você fecha o navegador ou quando a sessão termina.
Finalidade
Coletam informações sobre como você usa o site, como as páginas que você visitou e os links em que clicou. Nenhuma dessas informações pode ser usada para identificá-lo. Seu único objetivo é possibilitar análises e melhorar as funções do site.

Você pode desabilitá-los alterando as configurações do seu navegador, mas saiba que isso pode afetar o funcionamento do site.

Chrome

Firefox

Microsoft Edge

Internet Explorer